All three fibers work together in one network. Here is how to choose the right one for each segment of your FTTH project.
| Parameter | G.652D | G.657A1 | G.657A2 |
|---|---|---|---|
| Standard | ITU-T G.652.D · IEC 60793-2-50 B1.3 | ITU-T G.657.A1 · IEC B6_a | ITU-T G.657.A2 · IEC B6_b |
| Attenuation @1310 nm | ≤ 0.40 dB/km | ≤ 0.40 dB/km | ≤ 0.40 dB/km |
| Attenuation @1550 nm | ≤ 0.30 dB/km | ≤ 0.30 dB/km | ≤ 0.30 dB/km |
| Water peak (1383 nm) | Low water peak | Low water peak | Low water peak |
| Min. bend radius (long term) | 30 mm | 10 mm | 7.5 mm |
| Cladding / coating Ø | 125 / 245 µm | 125 / 245 µm | 125 / 245 µm |
| Mode field diameter (MFD) | @1310: 9.2±0.35 µm · @1550: 10.4±0.5 µm | @1310: 9.2±0.35 µm · @1550: 10.4±0.5 µm | @1310: 9.2±0.35 µm · @1550: 10.4±0.5 µm |
| PMD coefficient | ≤ 0.15 ps/√km | ≤ 0.15 ps/√km | ≤ 0.15 ps/√km |
| Cable cut-off wavelength | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm |
| Compatibility with G.652D | — | Fully compatible | Fully compatible |
| Typical position in network | Backbone · metro · feeder | FTTH drop · indoor cabling | FTTH last 100 m · tight corners · indoor |
| Typical product form | Bare fiber · outdoor cable | Drop cable · indoor cable | Flat drop cable · tight-bend indoor |
The industry-standard single-mode fiber for trunk, metro and feeder segments. Lowest cost per fiber-km; bend performance is sufficient where cables follow generous routes.
Bend radius down to 10 mm. A safe choice for drop segments with moderate routing demands; fully splicing-compatible with existing G.652D plant.
Bend radius down to 7.5 mm — around tight wall corners, through pre-embedded ducts and indoor raceways with negligible added loss. The mainstream choice for FTTH drop and indoor cabling.